Skip to main content

Table 5 Results from standard digital radiography in different gender group

From: Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research

 

Female in DR (n = 22)

Male in DR (n = 11)

p-value

Entrance Skin Dose (μGy)

 - Sternal Notcha

126.1 (33.2)

170.5 (64.1)

0.01*

 - Nipple Linea

469.6 (165.2)

625.1 (273.5)

0.05

 - Symphysis Pubisa

709.3 (276.4)

756.1 (343.4)

0.68

Effective Dose (μSv)

64.0 (21.1)

74.4 (26.9)

0.23

Organ Dose (μGy)

 - Thyroid

11.6 (3.1)

13.5 (5.3)

0.31

 - Lung

99.8 (31.5)

126.1 (49.5)

0.07

 - Reproductive Organ

83.6 (31.4)

36.8 (12.9)

<0.01*

DAP (mGycm2)

546.9591 (219.2)

734.7273 (309.1)

0.05

  1. *indicates statistically significant difference at 0.05 level
  2. aentrance skin doses were obtained at dorsal sites (the back of each volunteer) at the level of corresponding anterior structures